All pages

Servers

A server's controller (BMC) is added as a KVM is, in Add KVMs and servers, and spoken to over Redfish. Its password goes only where the address answers as a Redfish controller: an error page or another device's sign-in there gets nothing.

On the card

On or Off, health, temperatures and fans.

The server's menu

ActionWhat it does
Power on or Shut downAs the server is; Shut down asks the operating system
Hold power buttonCuts the power
Press reset buttonResets the server
Start into BIOS setupRestarts the server into its BIOS setup
Locator light on or offThe light on the machine itself, for whoever stands in front of the rack
Restart controllerRestarts the BMC
Open consoleOpens the controller's own page in your browser

Those that could do harm ask first, naming the machine.

The server's own screen

Where its controller runs AMI MegaRAC or OpenBMC, the server's screen is on its card and live in its large view. Keyboard, mouse and typed text work as the console allows.

On AMI MegaRAC, somebody else at the console is not pushed off. Where the controller switches the server's own monitor off while its console is open, or does not say whether it does, qKVM leaves the console alone, and the card says so.

When BIOS setup is only queued

Some controllers only queue the change. qKVM then follows the controller's task for up to a minute, and restarts the server once it shows the change. Where qKVM cannot tell, the card says "The controller queued a change qKVM could not follow; check the boot override in its BMC".

That note stays until a later start into BIOS setup on that server ends as it should, or the server is taken off the wall. If qKVM ended before the controller answered, the card says at the next start that the controller may have queued it.

One card, one server

A server is known by its UUID, the number its board gives for itself, not by its certificate. A card is not taken for another computer of its controller, such as another node of a chassis. Another server in the card's place is said on its card and sent nothing.

The few cases this cannot tell are listed in Changes.

Is it this server?

A card added while its server gave no UUID asks once, when the server gives one: Is it this server? Until you answer, nothing but looks goes to it: no power, no boot override, no keys, no console.

AnswerWhat happens
Yes, it isThe card knows the server by that number from then on, with no password typed
NoThe card refuses that computer from then on, on or off

After a No, to put your own server on that card: switch it on from its BMC's own page, then edit the card and type its password. Or remove the card and add it again.