A server's controller (BMC) is added as a KVM is, and spoken to over Redfish, with a session of its own that the program gives back when it ends. Its password goes only where the address answers as a Redfish controller: an error page or another device's sign-in there gets nothing.
- Its card shows On or Off, health, temperatures and fans.
- Its menu: Power on or Shut down (which asks the operating system), as the server is; Hold power button (cuts the power); Press reset button; Start into BIOS setup; Locator light on or off (the light on the machine itself, for whoever stands in front of the rack); and Restart controller. Those that could do harm ask first, naming the machine.
- Its own screen. Where its controller runs AMI MegaRAC or OpenBMC, the server's screen is on its card and live in its large view, with keyboard, mouse and typed text as the console allows. On AMI MegaRAC, somebody else at the console is not pushed off, and where the controller switches the server's own monitor off while its console is open, or does not say whether it does, qKVM leaves the console alone, and the card says so.
- Open console opens the controller's own page in your browser.
Start into BIOS setup
Where a controller only queues that change (it answers that it will do it later), qKVM follows the controller's task for up to a minute, and restarts the server once the server shows the change. Where it cannot tell, it says so, and the card says "The controller queued a change qKVM could not follow; check the boot override in its BMC" until a later start into BIOS setup on that server ends as it should, or the server is taken off the wall. Where qKVM ends before the controller has answered (quit, a crash, Windows' restart), the card says at the next start that the controller may have queued it. Check the override in the BMC yourself.
One card, one server
A server is known by the numbers its board gives for itself (its UUID), not by its certificate, and its password goes to its own address and to no other. A card is not taken for another computer of its controller, such as another node of a chassis: each press reads the controller's list of computers anew, a command goes only to the computer it was decided for, and another server in the card's place is said on its card and sent nothing. The few cases this cannot tell are in the changes of 0.2.0.
A card added while its server gave no UUID (some boards give none while they are off) asks once, when the server gives one (switched on, say): Is it this server?
- Yes, it is: the card knows it by that number from then on, with no password typed.
- No: the card refuses that computer from then on, on or off. To take your own server there after that, once it stands there again, switch it on from its BMC's own page, then change the card and type its password; or remove the card and add it again.
Until you answer, nothing but looks goes to it: no power, no boot override, no keys, no console.
A server card from 0.1.x may refuse everything after the upgrade, until you act: see Coming from 0.1.x.